Maytag Dryer Error PF – Power Failure – Cycle Interrupted by an Outage
PF isn't a fault: the Maytag dryer lost power mid-cycle. Press and hold Start to resume, or Power to clear it.
At a glance
Severity: Minor
- Meaning
- Power Failure – Cycle Interrupted by an Outage
- System
- Maytag · Dryer
- Typical repair cost
- $0–$300
- DIY difficulty
- Very easy
Maytag uses PF to tell you a power failure interrupted the drying cycle. It's a notice, not a breakdown – the control simply remembers that it lost power and waits for you to decide whether to continue. Press and hold Start to resume the cycle or press Power to clear the display. Maytag also notes that PF can appear without an obvious outage: electrical noise on the supply that the control reads as the wrong voltage, or buttons pressed within the first 10 seconds after power returns. If PF keeps showing up with no storms or outages, the cause is on the supply side – a tripping breaker, a loose cord connection or a worn outlet.
How it looks on the display
Model families & display variants
| Model family | Shows | Note |
|---|---|---|
| Maytag dryers with a numeric display | PF | Power failure interrupted the cycle – not a component fault. |
| Commercial-grade residential Maytag dryers | PF | Same meaning; same Start / Power response. |
| Whirlpool-built sister brands | PF | Whirlpool and Amana dryers on the same controls use PF for the same event. |
Safety first · Consult a professional
If the cord, plug or outlet is warm, discolored or smells burnt, switch off the breaker and have an electrician check it – a loose 240-volt connection can overheat. Don't open the terminal block cover with power on.
- Unplug the appliance or switch off the breaker before opening any panel. Mains voltage can kill.
Symptoms
- PF on the display when you come back to the dryer
- Laundry is still damp and the cycle stopped partway
- Other appliances or clocks in the house were reset too
- PF keeps appearing on days without any outage
- The dryer's breaker is found half-tripped or off
Possible causes
Ranked by how often each cause is behind this code (editorial estimate).
- Actual power outage or brief utility interruption
- Electrical noise or a voltage dip read by the control as a power loss
- Keys pressed within 10 seconds of power being restored
- Dryer breaker tripping or a worn breaker
- Loose plug, worn outlet or loose wire at the dryer's terminal block
- Control board fault falsely detecting power loss
Fix it step by step
Confirm it was an outage
Check whether microwave or oven clocks are blinking. If they are, PF simply recorded that event and no repair is needed.
Restart the load
Press and hold Start to continue drying. If the clothes sat a long time, choose a short timed cycle to finish them and reduce wrinkles.
Check the breaker
At the panel, the dryer's double-pole breaker should be firmly on. If it trips again during drying, stop using the dryer and have the circuit or the dryer checked.
Tools: Flashlight
Look at the plug and outlet
With the breaker off, pull the dryer out and inspect the cord and outlet for discoloration, melting or a loose fit. Any heat damage means an electrician, not a reset.
Tools: Flashlight
Watch for repeat PF codes
If PF shows up regularly without outages, note the times and whether other large loads (AC, well pump) start at the same moment. That pattern helps an electrician find voltage dips on the supply.
How to reset PF
- Press and hold Start to resume, or press Power to clear.
- After an outage, turn off the dryer's breaker for a few minutes, then back on.
- Wait about 10 seconds after power returns before pressing any keys.
- Watch the display for a few minutes to confirm PF doesn't return.
Where the parts are
- 1Lint filter
- 2Exhaust vent
- 3Heating element
- 4Condenser
- 5Motor
- 6Temperature sensor
- 7Door switch
Repair options & costs
| Repair | DIY? | Estimated cost |
|---|---|---|
| Resume or clear the cycle | Yes | $0 |
| Breaker reset | Yes | $0 |
| Replace worn 240 V dryer outlet (electrician) | No | $120–$250 |
| Replace dryer power cord / tighten terminal block | No | $25–$150 |
| Replace a weak double-pole breaker (electrician) | No | $150–$300 |
Rough US estimates; technician call-out fees vary by region. Not a quote.
When to call a technician
Call an electrician if the breaker trips during drying, if the outlet or cord shows heat damage, or if PF keeps appearing without any outages. Contact Maytag service if the supply checks out and the control still reports PF.
Frequently asked questions
Is PF on a Maytag dryer a sign something is broken?
Usually not. PF means the cycle was interrupted by a power failure; press and hold Start to continue or Power to clear.
Why does my Maytag dryer show PF when the power never went out?
The control can read electrical noise or a short voltage dip as a power loss. Pressing keys in the first 10 seconds after power-up can also trigger it; frequent PF codes deserve an electrician's look at the circuit.
Will my clothes be damaged if PF stopped a hot cycle?
Clothes left hot and damp in the drum can set wrinkles and, in rare cases with oily fabrics, heat up on their own. Resume the cycle or take the load out and spread it out to cool.