Not heating: Codes, Causes & Fixes
When a dishwasher, washer, dryer or oven runs but doesn't heat, the usual suspects are the heating element, the temperature sensor (thermistor) that controls it, a safety thermal fuse or – in dryers – restricted airflow that trips the overheat protection. Error codes often distinguish between a sensor fault and a heater circuit fault, which helps decide what to test. Heating elements run on mains voltage, so replacement is a job for a technician unless you are qualified; for boilers see “No heat or hot water”.
71Codes
3.0Average severity
17%High or critical
41%DIY-friendly
Severity distribution
Most viewed
U4
Daikin · Air Conditioner / Heat Pump
The indoor unit has lost its data link with the outdoor unit, so the system can't cool or heat.
Moderate
E6
Mitsubishi Electric · Air Conditioner / Heat Pump
The indoor unit isn't getting valid signals back from the outdoor unit over the S3 wire.
Moderate
D80
LG · Dryer
LG Flow Sense detected restricted airflow in the vent. The dryer still runs, but lint buildup…
Moderate
HE
Samsung · Dryer
The Samsung dryer isn’t heating as expected – often no heat at all. Check power, gas supply…
Moderate
F2
GE Appliances · Oven / Range
The control saw the oven running hotter than its safety limit and shut the heat off.
High
F3
Whirlpool · Oven / Range
The control can't get a valid reading from the oven temperature sensor, so it won't heat…
Moderate
All codes (71)
11
Fujitsu · Air Conditioner / Heat Pump
Error 11: the serial data link on terminal 3 between the Fujitsu indoor and outdoor units has…
Moderate
126
Trane · Air Conditioner / Heat Pump
126 on a Trane ComfortLink II thermostat: it lost its data link to the furnace, air handler…
Moderate
13
Carrier · Air Conditioner / Heat Pump
A limit or rollout switch stayed open too long, so the furnace has locked itself out for 3…
High
1dL
Goodman · Air Conditioner / Heat Pump
IdL (often read as 1dL) is not a fault: the furnace is powered and waiting for a call from…
Minor
31
Carrier · Air Conditioner / Heat Pump
The inducer couldn't prove a clear vent, so the pressure switch stayed open and the burners…
Moderate
33
Carrier · Air Conditioner / Heat Pump
A high-temperature safety switch opened, usually because too little air is moving through…
Moderate
434
Lennox · Air Conditioner / Heat Pump
The Lennox outdoor control can't talk to the inverter drive that runs the variable-speed…
Moderate
51
Fujitsu · Air Conditioner / Heat Pump
Error 51: the indoor fan ran far slower than commanded for about a minute, so the Fujitsu unit…
Moderate
A1
Daikin · Air Conditioner / Heat Pump
The indoor unit's circuit board couldn't load or apply its settings, so the head refuses to run.
Moderate
AF
Whirlpool · Dryer
Whirlpool's vent monitor found restricted airflow: clogged lint screen or vent, or a crushed…
Moderate
C-21
Samsung · Oven / Range
The Samsung range sensed too high an oven temperature – real overheating or a bad sensor…
High
CH05
LG · Air Conditioner / Heat Pump
CH05: the LG indoor unit hears nothing back from the outdoor unit, so the compressor…
Moderate
CH10
LG · Air Conditioner / Heat Pump
CH10: the indoor unit's fan motor isn't turning or isn't reporting its speed, so the unit shuts…
Moderate
CH21
LG · Air Conditioner / Heat Pump
CH21: the outdoor inverter's power module saw a dangerous current peak and cut power…
High
CH38
LG · Air Conditioner / Heat Pump
LG's protection stopped the system because the refrigerant level or pressure looks too low.
High
D80
LG · Dryer
LG Flow Sense detected restricted airflow in the vent. The dryer still runs, but lint buildup…
Moderate
d90
LG · Dryer
LG's duct sensor found a severe exhaust restriction (about 90%). Clean the whole vent before…
High
d95
LG · Dryer
d95 is LG's highest duct-blockage level: about 95% restricted. Don't run more loads until…
Critical
dHE
LG · Washer-Dryer
dHE on an LG washer dryer combo: the drying system failed – usually the drying fan motor.
Moderate
E003
Navien · Water Heater / Boiler
The heater sparked and opened its gas valve, but never saw a flame – often a closed valve or no…
Moderate
E01
Bosch · Dishwasher
The main control found a fault in the circuit that powers the heat pump. Start with a breaker…
Moderate
E012
Navien · Water Heater / Boiler
The burner lit, then lost its flame signal mid-cycle – think gas pressure, grounding or a dirty…
Moderate
E04
A. O. Smith · Water Heater / Boiler
The electronic thermostat can't power the upper element; the lower one still works, so hot…
Low
E-08
Samsung · Oven / Range
The oven didn't warm up to about 100°F within 10 minutes of starting, so the range stopped…
Moderate
E09
Bosch · Dishwasher
The Bosch sees no working heater circuit. On most models the heater is built into…
Moderate
E09
Bosch · Dryer
Bosch lists E09 as an electronic fault for a technician; heat-pump models often have a bad…
Moderate
E1
Goodman · Air Conditioner / Heat Pump
E1: the low-stage pressure switch reads closed before the inducer starts, so the furnace won't…
Moderate
E1
Gree · Air Conditioner / Heat Pump
E1: refrigerant pressure on the high side got too high and the Gree unit stopped the compressor…
Moderate
E101
Samsung · Air Conditioner / Heat Pump
The indoor unit waited too long for the outdoor unit to answer on the F1/F2 link and shut…
Moderate
E110
Navien · Water Heater / Boiler
The fan can't move enough air through the vent system – most often a clogged intake filter…
High